4520--Heat Exchanger for ME Building
Process Number 36C26122Q0226
Dates:
36C26122Q0226
Department/Ind. Agency:VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier:VETERANS AFFAIRS, DEPARTMENT OF
Sub Command:261-NETWORK CONTRACT OFFICE 21 (36C261)
Office:261-NETWORK CONTRACT OFFICE 21 (36C261)
General Information:
(utc-08:00) pacific standard time, los angeles, usa
Updated Published Date:(utc-08:00) pacific standard time, los angeles, usa
Original Published Date:0000-00-00 00:00:00
Original Response Date:feb 10, 2022 02:00 pm pst
Inactive Policy:manual
Original Inactive Date:apr 11, 2022
Initiative:- None***--***
Classification:
4520 - space and water heating equipment
NAICS Code:332410 - power boiler and heat exchanger manufacturing
Description:
The purpose of this Request for Information is to conduct market research. This is not a solicitation, but rather an inquiry. The VA is seeking to procure a heat exchanger for one of the VHA medical centers in northern California. No installation will be required. If your firm can provide the heat exchanger that is described below, please respond by providing a response to this RFI to include product information and pricing via email please include shipping costs in your response. Please identify your socio-economic status (SDVOSB,VOSB, WOSB, HUBZone, etc.) Brand Name Item or Equal : Spirax-Sarco HSP-25-200P-SS-P-25 Heat Exchanger Salient characteristics: Qty (2) Connected to one Vented 3X2 PTC Pump Package Sized to heat 200 GPM of water from 160°F to 180°F, when supplied with 25 psig steam to the control valve. Unit is shipped complete with the following Qty (2) High Limit Valve: 3"M40SI 2RB ISO ANSI 150 60SGL340S/10FC24AC Qty (2) Manual Steam Isolation Valve: GATE VALVE, 3 ANSI 125 CI FIG. 1787 POWELL Qty (2) Steam Strainer: 3 ANSI 125 CI-125 STR 60-100M Qty (2) ASME CODE Stamped (150 psig) Plate and Frame Heat Exchanger with Single Wall 316 Stainless Steel plates and EPDM gaskets o Alfa Laval - TS6-MFG, 24 plates, Alloy 316 Qty (2) Single Valve Config o 2 1/2LEA33PTSUSS.2 Cv 73.0 ANSI PN9236E (15-30)100G MPC2A Qty (2) 4 SS COMPOUND PG 30/60 HG/PSI, 1/4 NPT Pressure gauge downstream of control valve Supplier Capability: - Do you have a local representative that is able to commute to Palo Alto, CA if in person support is necessary?                                                    - Can you supply all the equipment that is being requested?                                     - Can you provide on-going equipment support if needed? Delivery: The VA Medical Center is in Palo Alto, CA. The address is 3801 Miranda Avenue, Palo Alto, CA 94304-1290, building 50. FOB Destination (shipping included in price) Please email your response to Destiny Dyson via email: destiny.dyson@va.gov by no later than 2:00PM PST on 02 February 2022. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Attachments / Links:
| Document | Size | Updated date | Download |
|---|
Contact Information:
10535 HOSPITAL WAY
MATHER , CA 95655
USA
Primary Point of Contacts:Destiny Dyson